Lithium battery test chiller is a commonly used test equipment to simulate the working condition of lithium battery in low temperature environment to evaluate the performance and reliability of lithium battery. However, due to the special nature of the chiller, the use of the process requires attention to some matters and maintenance points. The following is a detailed introduction to the use of lithium battery test chiller precautions and maintenance points.
1. Precautions for use:
1.1 Adaptation of the environment: the chiller should be placed in a well-ventilated and dry dust-free environment, avoid direct sunlight and high temperature environment.
1.2 Stable power supply: chiller power access must be stable, voltage fluctuations should not be too large, so as not to affect the normal operation of the equipment.
1.3 Temperature control: in the process of using the chiller, should be set according to the need for a suitable range of operating temperatures, and through the temperature control instrumentation to monitor and regulate, to avoid the temperature is too low or too high to affect the test results.
1.4 Safe operation: In the process of using the chiller, it should be operated in strict accordance with the operating instructions to avoid mishandling or improper operation leading to equipment failure or personal injury.
2. Maintenance points:
2.1 Regular cleaning: regularly clean the accumulated dust and dirt inside and outside the chiller, especially the radiator and filter and other parts, to ensure the heat dissipation effect and smooth air flow.
2.2 Water quality treatment: Regularly test and keep the water quality of the chiller clean and stable to avoid water pollution and scale clogging, you can use water treatment agent to treat the water quality.
2.3 Water filling operation: Before filling water, make sure that the power supply of the chiller has been cut off, and carefully check the water level display to make sure that the water level is sufficient and avoid too high or too low.
2.4 Radiator Maintenance: The radiator is the core component of the chiller, check the condenser and evaporator of the radiator regularly for scaling or clogging, and clean or replace them if necessary.
2.5 Filter cleaning: Clean and replace the filter of the chiller regularly to ensure the filtering effect and clean water quality.
2.6 Regular maintenance: Regularly check the working status of the compressor, electrical components, sensors and other key components of the chiller, if there is any damage or malfunction need to be repaired or replaced in time.
2.7 Standby maintenance: If there is a standby chiller, the standby machine should be regularly checked and maintained to ensure that the standby machine can work properly when needed.
In summary, the use of lithium battery test chiller precautions and maintenance points including adaptation to the environment, stabilization of power supply, temperature control, safe operation and other aspects of the precautions, as well as regular cleaning, water quality treatment, water injection operation, radiator maintenance, cleaning filters, regular maintenance, standby maintenance and other aspects of the maintenance points. Only the correct use and regular maintenance of the chiller can ensure its normal operation and extend its service life, while ensuring the accuracy and reliability of the test results.
Manager Hong:+86 15298871053
Company Phone:+86 400-600-7626
Company Email: lingheng@liat.cn
Company website: www.liat.cn
Address:No.178,Puhui Road,Jiuting Town,Songjiang District,Shanghai,China.
Factory Address: Building 6, No. 208, Changqing Road, Wujiang District, Suzhou, China
Mr. Hong:+86 15298871053
7*24 hour service hotline